3/4 Crown Restoration: restore the tooth with glass ceramic crown with Helios 500

View: 219 times    / Time: 2025-02-24

• Case Provider: Dr. Hakan Çolak

• Solution Used: Eighteeth Helios 500 Intraoral scanner and EXOCAD

• The workflow initiated with scanning using the Helios 500 and subsequent file importation into Exocad for further design and planning.

• About the Dentist

This case comes from Dr, Hakan Çolak in Turkey, He graduated from the Marmara University School of Dentistry in 2008 and received PhD in 2013 from Restorative Dentistry. He has been published many papers at international dental journals. He has been acting as an Editor-in-Chief of European Journal of General Dentistry since 2012. His main interest area is Direct Restorations, CAD/CAM systems, Adhesive Ceramic Restorations and Endodontics. Currently he is working as private practitioner in Kocaeli Turkey.

• Case

A 42 year old female patient presented with a large amalgam restoration on the mandibular left first molar with lingual cusp fracture that was experiencing transient cold sensitivity, which were not persistent, along with sensitivity to sweets.

The recommended treatment was a conservative 3/4 ceramic crown restoration.

• lnitial

1

• Treatment Process

After amalgam restoration was fully removed decay on cavity floor and mesial and distal proximal sides was detected

2

Decay was carefully cleaned without plural exposure and optimized with highly filled flowable composite.

3/4 crown preparation was done in order to preserve as much tooth structure as possible

3

Scanning with Helios 500

4

Scanned files imported to EXOCAD for further design

Immediate post-op of bonded glass ceramic crown

5

1 month post-op.

Final X-ray